Chapter 4
Fuel Filter Element Overview-Gas Generator
Since water is heavier than fuel it will settle in the bottom of
the element. Periodically replace the fuel lter element With
a strap or tted wrench turn the element counterclockwise
until loose. Unscrew by hand and release from the lter
body. Use an environmentally safe container to catch any
contaminated fuel. Dispose of according to local or state
regulations.
Coat the O ring (gasket) of the new element with oil. Hand
tighten by turning clockwise until tight.
Note: Water in gasoline or diesel fuel will gather at the
bottom of the container. Since it is heavier water will
normallly appear as a different color and consistency and
normally can be spotted as in moves back and forth.
Run blower for at least 4 minutes. Start engine and check
for leaks.
FILTER
ELEMENT
FILTER
BODY
TYPICAL GENERATOR GAS FUEL FILTER
Typical Electrical System
The generator starting system normally uses the port
cranking battery. The generator is usually started at the 12
volt ship’s control panel located in the salon but it can also
be started using the remote instrument panel located at the
generator itself as needed. The latter is especially useful
while maintenance is being conducted. The generator
remote instrument panel features temperature, oil, DC
volts, hour meter gauges and pre-heat, start and stop
switches. The starting switches can be reached through an
access panel at the sound shield.
One of the switches is set up different on the ship’s main
control panel. Here the pre-heat switch is called an “on”
switch. The start and stop switches by name and function
are identical to the switches on the remote panel.