51
Systems
POSSIBLE PROBLEMS/SOLUTIONS-
FRESH WATER SYSTEM
1. Fresh water pressure pump cycles on
and off. Normally this type of action indi-
cates a water leak in the system. Check all
fresh water system related equipment on
the deck, cabin, and engine compartment
for leaks. Do not forget wash down equipment including
spigots. Look for puddled or dripping water.
2. Using potable water system the water pressure is weak.
Check the fresh water pressure pump lter for debris.
Also, make sure the potable water tank level is suf cient
at the salon monitor.
3. Water at sink or shower is hammering and has air bub-
bles in it. Check for air leaks in the system along with low
water levels in the potable water tank.
4. Water is backing up in the shower. Find the correct
shower sump pump. If it is full of water even when run-
ning there normally is a clog at the pump screen. Clean
as needed.
5. There is no water at any of the fresh water related equip-
ment such as faucets, showers and wash downs. Check to
make sure the fresh water pressure pump breaker is on.
Also, check the fresh water monitor for tank levels at the
salon control panel.
6. The water system has a bad odor. Use the fresh water
pressure pump to drain the fresh water system. Do not
drink the water as it may be contaminated. Sanitize the
water system as explained earlier in this chapter
7. There is no hot water. Turn the hot water heater break-
er to the off position. Remove the back cover on the wa-
ter heater and check the reset button. Push to reset. Also,
the heating element may of malfunctioned. At this point,
call a service technician.
8.. Low water pressure especially while showering. Make
sure accumulator tank is cycling properly.
Typical Accumulator Tank
Located in the engine room close to the fresh water
pump is the fresh water system accumulator tank. This
component provides extra water pressure especially dur-
ing high demands with the on board fresh water system.
This may include showering, using a transom shower, or
washdown faucet.
Note that the accumulator tank normally requires no ser-
vice. It contains a pre-determined amount of air pres-
sure for the unit to preform ef ciently. Should the unit
leak down it will need to be rein ated with air. There is a
tting on the end of the tank for this purpose. Contact
your closest Regal dealer for more information.